Phone: 1-800-569-1291   Fax: 1-860-693-2197

logo

11054

Roll formed of 1/32″ material
The equivalent rectangle for all conductors is 1″ x 1/4″. Supports are required at intervals of: 3′ on curves, 3′-4″ for lateral mount, 5′ standard.

The solid copper conductors are supplied in 20′ lengths, covered, with connector clamp and case. Conductor bar and covers may be ordered separately for replacement purposes.

Specifications

List Price

N/A

Logo

N/A

Manufacturer

N/A

Brand

N/A

Amperage Rating A

500

Material

Solid Copper

Cover Type

High Heat

Weight

24.6 lb
0.16 lb·ft

Length

20 ft

Cross Sectional Area

0.1477 in2

Expansion Coefficient F

0.000009 ºF

Resistance R (for DC) at 20º C

40 µΩ/ft

Reactance X

60 µΩ/ft

Phase Corrected Impedance Z at 20º C

70

Support Spacing

5 ft

Normal Ambient

-60 to 400 ºF